• Fully electronic, direct actuated control system ensures fly-by-wire operation.
• Suitable for operation with Woodward 505 XT and Voith DTc Electronic governors.
• Independent control oil system ensures long life and reliability.
• Upto 7 stages and 10250 RPM For Maximum Efficiency.
• Critical speed above rated operational speed ensures ease of startup and operation.
• Suitable upto 69 Bar (a) Inlet Pressure.
• Multiple inlet control valves for Part load Nozzle control.
• Standardised vibration monitoring system
• Mechanical and electronic protections for low oil pressure and overspeed.
• Complete Labyrinth type steam seals.
• Provision for externally controlled extraction upto 37 bar.
• Meets API 611 Specifications.